Evaluate an air-quality sensor with a community group
Compare a sensor with a suitable reference through an approved collocation plan and document its limits without claiming certification or calibration.
achievement

Saves privately on this device. No account needed.
Read the full guide
Plan a community air-sensor check that answers one question
Work with a community group to compare an air sensor with a clear question, consistent placement, good notes, and careful limits on what the readings can prove.
Plan the experience
Learn how a community group evaluates an air sensor against a reference and documents data quality.
Planning estimates, not a price quote or a deadline. Your version may vary.
- Time
- Several planning sessions and the group’s required comparison period.
- Cost
- Borrowing helps; a sensor and approved mounting may otherwise cost moderately.
- Where
- A group-approved monitoring location with permission and safe installation.
Before you start
Read the collocation guide with an experienced group. Confirm the pollutant, sensor, reference access, duration and analysis plan before treating any device as a trustworthy local monitor.
How you would actually start
Define the comparison
Ask what the sensor measures and which reference is appropriate. Agree data intervals, units and placement with the group. Record environmental factors and manufacturer settings that could affect the comparison before collecting data.
Collect paired observations
Have a competent person install the equipment safely at the approved site. Keep a maintenance and interruption log. Do not expose the device to smoke or other hazards merely to generate more interesting readings.
Review performance honestly
Compare time-aligned sensor and reference data using the group’s method. Document missing values and limits rather than calling a correlation a universal calibration. Apply any correction only with the group’s justification and retain the raw record.
What counts as done
A paired comparison has been reviewed with the group and its useful range and limitations are documented.
Checking a sensor’s performance and correcting its data are related but different tasks; name which one you actually completed.
When you finish, mark it fulfilled in My list. You can remember it in your weekly journal.
Useful sources
- Air sensor collocation and evaluation
United States Environmental Protection Agency · Read EPA’s collocation guidance with your group to plan a reference comparison and document sensor limitations.
Guide updated 2026-11-07